125 Greenwich Street
Rafael Viñoly tower in the Financial District, 272 residences.
125 Greenwich Street, 10006
ALSO KNOWN AS The Greenwich by Rafael Viñoly
125 Greenwich Street was designed by Rafael Viñoly Architects, with interiors by March and White, on a narrow Financial District site. Rafael Viñoly Architects describes the structure as two shear walls shaped like I beams running the height of the tower to support the core, which removes all but four of the interior columns.
That structure is the fact that decides the apartments. The floor plates are close to column free and the perimeter is curved floor to ceiling glass with rounded corners, so nothing loads the outside wall and nothing penetrates it. Storage, millwork and anything heavy move inboard to the core walls, and a plan drawn on the assumption that a wardrobe or a bookcase can sit against a window wall has to be redrawn.
A glass perimeter over hard floors leaves the acoustic and the thermal work to soft materials. Upholstery, rugs and drapery are doing structural work in these rooms rather than decorative work, and a room specified without them will be bright, loud and cold at the glass.
Hexagonal mechanical floors sit between the residential volumes and act as wind breaks. They are also the levels where the stacks change, which is worth knowing before assuming a riser runs straight from one apartment to the one above it.
The tower is an argument that a slender site is a structural problem before it is a planning one. Solve the wind and the column free plan follows, which is the opposite order from how most apartment buildings of this size are drawn.
Within walking distance
Building facts
Built
2016
Floors
71
Residences
272
New York City Primary Land Use Tax Lot Output, version 26v1. Tax lot 1000517502.
Public records show 22 THAMES STREET was built in 2016 and rises 71 floors with 272 residential units (NYC MapPLUTO, version 26v2). No HPD violations are recorded for this lot (NYC Open Data, as of October 28, 2026).
Public record
Total units
273
NYC MapPLUTO 26v2, NYC Open Data. Tax lot 1000517502. Violations and permits as of October 28, 2026.
Condo documents are recorded at unit level. Search a unit to see them.
DOB legacy violations
DOB BIS · NYC Open Data
43 resolved, most recent Dec 22, 2025
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
CIANOW CRM Violation Dismissed · disposed Dec 22, 2025
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
CIANOW CRM Violation Dismissed · disposed Dec 22, 2025
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
CIANOW CRM Violation Dismissed · disposed Dec 22, 2025
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
CIANOW CRM Violation Dismissed · disposed Dec 22, 2025
VIO23-50312
VIOLATION CORRECTED · disposed Mar 31, 2024
ADDITIONAL INFORMATION.THE DEPT RECEIVED A COMPLAINT FROM THE PUBLIC ON 10/17/23 VIA AN EMAIL.THE COMPLAINT DESCRIBES"CRACKS & CREVICES" IN THE BLDG UNDR CONST&IT INCLUDED SEV PHOTOS OF THE BLDG.THE BLDG OWNR TO HIRE A P.E TO CONDUCT A WALK THRU VISUAL INSP OF THE ENT BLDG CNCRTE STRCTRL ELEMENTS, INCL SHEAR WALL
OWNER COMPLIED WITH REQUIREMENTS OF DOB ORDER. · disposed Dec 26, 2023
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2021
NB W/ 1ST TCO LESS THAN 10 YRS OLD AT TIME DUE TO COMPLY · disposed Jan 16, 2023
FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019
CAW FULL DEMOLITION OF A 10 STORY BUILDING SIGNED OFF 12/13/2013.(CAW). · disposed Sep 24, 2019
FAILURE TO PERFORM CATEGORY 5 INSPECTION
EVCAT5 DM#121465878SO/12/13/13 · disposed Jun 2, 2019
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
CHALLENGE APPROVED · disposed Jun 3, 2019
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
JTR INV 13351359 PAID ON MARCH 9 2018 · disposed Mar 12, 2018
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
PAID 13382987 · disposed May 21, 2018
ADDITIONAL INFO:ON 2/26/16 A LARGE NEW 2'+/- DEPRESSION IN THAMES ST WAS OBSERVED ALONG TANGGENT PILE SOE FOR THAMES ST THAT IMPACTED ALL UTILITIES ALONG THAMES ST BTWN TRINITY & GREENWICH ST. REMEDY:BY COB 3/4/16 PROVIDE DEPT W/COPIES OF PERMITTED SOE DWGS
DISMISSAL AS PER GEOFF EISELE. · disposed Feb 6, 2018
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
CAT 1 DEMO#121465878 SO/12/13/2013 · disposed Apr 26, 2018
FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013
CAW · disposed May 14, 2014
PPN203 AOC SUB ON 07/19/12 BY CENTURY VERTICAL SYSTEM, TODD ROWAN, CERT #510-005 · disposed Nov 19, 2012
PPN203 AOC SUB ON 07/19/12 BY CENTURY VERTICAL SYSTEM, TODD ROWAN, CERT #510-005 · disposed Nov 19, 2012
PPN203 AOC SUB ON 07/19/12 BY CENTURY VERTICAL SYSTEMS, TODD ROWAN, CERT #510-00 · disposed Nov 19, 2012
083055 · disposed May 7, 2010
083046 · disposed May 7, 2010
083046 · disposed May 7, 2010
PPN203 AOC SUB ON 042310 BY PRECISION ELEV INSP. D ALBERTSON CERT#429003 · disposed Jun 10, 2010
PPN203 AOC SUBMITTED ON 02/23/2009 BY NEW YORK ELEVATOR CERT#481001 · disposed Mar 3, 2009
PPN203 AOC SUBMITTED ON 02/23/2009 BY NEW YORK ELEVATOR CERT#481001 · disposed Mar 3, 2009
PPN203 AOC SUBMITTED ON 02/23/2009 BY NEW YORK ELEVATOR CERT#481001 · disposed Mar 3, 2009
PPN203 AOC SUBMITTED ON 3/8/07 BY NEW YORK ELEVCERT. #481-011 · disposed Mar 7, 2007
PPN203 2YR TEST PERFORMED ON 06/26/2007 BY NEW YORK ELEV #481-001 · disposed Aug 7, 2007
PPN203 2YR TEST PERFORMED ON 06/26/2007 BY NEW YORK ELEV #481-001 · disposed Aug 7, 2007
PPN203 AOC SUBMITTED ON 110405 BY NEW YORK ELEV CERT#L481-011 · disposed Nov 6, 2005
PPN203 AOC SUBMITTED ON 022106 BY NEW YORK ELEV CERT#L481-011 · disposed Feb 21, 2006
PPN203 AOC SUBMITTED ON 110405 BY NEW YORK ELEV CERT#L481-011 · disposed Nov 6, 2005
PPN203 AOC SUBMITTED ON 12/21/2005 BY NEW YORK ELEV. & ELEC. CERT. #L481-011 · disposed Dec 27, 2005
PPN203 AOC SUBMITTED ON 12/23/03 BY NEW YORK ELEV. CERT. #L303-011 · disposed Jan 4, 2004
1P607
PPN203 AOC SUBMITTED ON 110405 BY NEW YORK ELEV CERT#L481-011 · disposed Nov 6, 2005
1F5182
PPN203 AOC SUBMITTED ON 110405 BY NEW YORK ELEV CERT#L481-011 · disposed Nov 6, 2005
1P607
AS PER INSPECTOR ROUTE SHEET · disposed Jul 25, 1999
1P608
AS PER INSPECTOR ROUTE SHEET · disposed Jul 25, 1999
1F5182
AS PER INSPECTOR ROUTE SHEET · disposed Jun 21, 1999
LL1081 FILED ON TIME · disposed Mar 3, 1997
LL1081 FOT · disposed Oct 31, 1994
(51)PROPERLY FUSE.(52)TAG GOVERNOR TO SHOW 5 YR. SAFETY TEST
(51)REPAIR CAR HANDLE ......(52)PROPERLY TAG GOVERNOR TO SHOW 5 YR. SAFETY TEST
(51)PROPERLY TAG GOVERNOR TO SHOW 5 YR. TEST
DOB BIS Violations (3h2n-5cm9), NYC Open Data. As of October 28, 2026.
ECB violations
Environmental Control Board · NYC Open Data
50 resolved, most recent Dec 8, 2024
FAILURE TO PROVIDE AND MAINTAIN ADEQUATE HOUSEKEEPING, INCIDENT OCCURRED WHEN WORKER WAS USING STILT AND FALL DUE TO POOR HOUSEKEEPING AND DEBRIS WAS ON FLOOR ALSO MATERIALS, CAUSING INJURY AND VIOLATING CODE 3
Penalty: $2,500 · paid: $2,500
TEMPORARY CONSTRUCTION EQUIPMENT ONSITE,EXPIRED PERMIT.AS NOTED:AT THETIME OF INSPECTION-CONSTRUCTION FENCE PERMIT WAS EXPIRED.CONSTRUCTION FENCE WAS INSTALLED ON THE SIDEWALK AT 133 GREENWICH ST BY 125 GREENWI
Penalty: $1,250 · paid: $1,250
EXPIRED SIDEWALK SHED PERMIT.AS NOTED:AT THE TIME OF INSPECTION.SIDEWALK SHED PERMIT WAS EXPIRED ON 07/24/2024.SIDEWALK SHED WAS INSTALLED ON SIDEWALK AT 133 GREENWICH ST BY 125 GREENWICH STREET OWNER'S CONTRAC
Penalty: $1,250 · paid: $1,250
A 72 STORY MAJOR BUILDING ACTIVE JOBSITE. I OBSERVED UNFINISHED WORK ON FACADE AT 9TH FLOOR SETBACK 10-15 FT ABOVE & LESS THAN 20 FEET FROM EDGE AT EXP#3,4. UPON FURTHER REVIEW OF ADJOINING PROPERTY ROOF. OBSER
Penalty: $2,500 · paid: $2,500
A 72 STORY MAJOR BUILDING ACTIVE SITE. I OBSERVED SIDEWALK SHED IN PLACE AT EXP#1. UPON FURTHER INSPECTION IT WAS OBSERVED THE I BEAMS HAD WOOD PLANKING ON TOP. ALSO THERE WAS MATERIALS STORED ON TOP OF SHED, W
3303.12 ELEVATORS.AT TIME OF INSPECTION RESPOND TO AN INCIDENT WHERE WORKERS WERE DOING HOT WORK ON THE ROOF TOWER OBSERVE 2 ELEVATOR WERE OUT OF SERVICE DUE TO THE FIRE .PROVIDE AND MAINTAIN ELEVATOR AS PER C
Penalty: $5,000 · paid: $5,000
RESPOND TO AN INCIDENT WHERE WORKERS WERE DOING HOT WORK ON THE ROOF TOWER. INSPECTOR REVEAL HOT WORK WAS BEING PERFORMED ON THE OUTSIDE OF THE TOWER. THE COMBUSTION MATERIAL WAS NOT REMOVED CREATE AN UNSAFE
Penalty: $25,000 · paid: $25,000
AT THE TIME OF INCIDENT AT 125 GREENWICH STREET, I OBSERVED SUSPENDED SCAFFOLD STORED AT EXPOSURE #4 ROOF OF 123 GREENWICH STREET ACCIDENTALLY SHIFTED DUE TO HIGH, WIND GUST CAUSING DAMAGES TO PARAPET WALL AT E
Penalty: $5,000 · paid: $5,000
A WORKER FELL OFF LADDER HURT HIS BACK AND WAS TAKEN TO HOSPITAL. PERMIT HOLDER JOB# 121183799 FAILED TO SUBMIT REPORT WITHIN 3 BUSINESS DAYS OF REQUIRED 16 ITEMS TO CODE 28-103.21 PER 28-103.21.1 VIA WEB FORM,
Penalty: $10,000 · paid: $20,000
PERMITHOLDER FAILED TO OBTAIN ELECTRIC PERMIT FOR STANDPIPE LOW PRESSURE ALARM SYSTEM IN CONTRARY WITH CODE. OBTAIN PERMIT
Penalty: $5,000 · paid: $5,000
SEC. 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OFAUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFWSSIONAL IN AN OFFICE BLDG 100 FEET OR MORE IN HEIG
BC3314.4.3/FAILRUE TO MAINTAIN DAILY LOG INSPECTION BOOK(PIPE SCAFFOLDS)AT TIME OF INSPECTION ON AN ACTIVE JOBSITE OF A 72 STORY NB OBSERVEDSEVERAL PIPE SCAFFOLDS ERECTED AT 9TH FLR AT EXP#1 & 4.UPON REQUEST FO
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPROVED AMENDMENTS.AT TIME OF INSPECTION ON AN ACTIVE JOBSITE,OF A 72 STORYNEW BUILDING OBSERVED AN APPROX.20FT IN HEIGHT SUPPORTED SCAFFOLD EREC
Penalty: $2,500 · paid: $2,500
FAILURE TO MAINTAIN DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33.(NO MANUFACTURER SPECIFICATIONS FOR SUSPENDED SCAFFOLD)AT TIME OF INSPECTION ON AN ACTIVE JOBSITE,OF A 72 STORY NB OBSERVED SUSPENDED SCAF
BC3301.7/FAILURE TO MAINTAIN DISPLAY ON SITE DRAWINGS DOCUMENTS REQUIRED BY CHAPTER 33.(NO DESIGN DRAWING FOR OVERHEAD PROTECTION(OHP)OVER THE LOADING DOCK AREA AND MAKESHIFT TIMBER PLATFORM AT 9TH FLR AT TIME
Penalty: $2,500 · paid: $2,500
FAILURE TO SAFEGUARD ALL PERSONS&PROPERTY AFFECTED BY CONST OPS.@TIME OF INSP OBSERVED DAMAGED CHAIR&PAVER &18"PC OF REBAR @6TH FL BALCONY OF 133 GREENWICH ST.DURING INSP OF 125 GREENWICH ST OBSERVED VERTICAL N
FAILURE TO MAINTAIN HOUSE KEEOING PER SECTION REQUIREMENTS. AT TIME OF INSPECTION OBSERVED IN ACTIVE CONSTRUCTION SITE WITH FERMING WORK ON PROGRESS, DURING INSPECTION NOTED ON THE 63 FLOOR TO 70 FLOOR ON STAIR
BC3301.2. FAILURE TO SAFEGUARD ALL PERSON EFFECTED BY CONSTRUCTION OPERATION. AT TIME OF INSPECTION I RESPONDED TO INCIDENT. I OBSERVED AT TIME CONSTRUCTION SITE WITH STAIL FERMING ON PROGRESS, DURING INSPECTIO
FALURE TO INSTITUTE AND MAINTAIN SAFETY EQUIPMENT MEASURES AND TEMPORARY CONSTRUCTION.NOTE:AT THE TIME OF MY INSPECTION OF A 71 STORY BUIDLING AT ROOF LEVEL RESPONDONG TO COMPLAINT #1501106 WHERE A WORKER FELL
Penalty: $10,000 · paid: $10,000
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPROVED AMEDNMENTS.NOTE:AT THE TIME OF MY INSPECTION OF A 71 STOYR BUILDING AT ROOF LEVEL CONSTRUCTION WORK IN PROGRESS.I OBSERVED OUTRIGGER BEAM
Penalty: $2,500 · paid: $2,500
FAILURE TO NOTIFY THE DEPT OF AN INCIDENT THAT RESULTED IN A FATALITY OR INJURY. DURING STRIPPING FORMWORK OPERAITON A WORKER FELL FROM A HEIGHT OF APPROXIMATELY 9 FEET. THE WORKER WAS TRANSPORTED TO A HOSPITAL
Penalty: $5,000 · paid: $5,000
3301.6.1;DESIGN SIZES AND CAPACITY OF MATERIALS,STRUCTURES,TEMPORARY CONSTRUCTION AND EQUIPMENT.NOTE:AT THE TIME OF MY INSPECTION OF A 71 STOYR BUILDING AT ROOF LEVEL CONSTRUCTION WORK IN PROGRESS I OBSERVED A
Penalty: $2,500 · paid: $2,500
ORIENTATION.NOTE:AT THE TIME OF INSPECTION OF A 71 STORY BUILDING AT ROOF LEVEL RESPONDING TO COMPLAINT #1501106 WHERE A WORKER FELT ON CONCRETE SLAB AFTER PANEL HE WAS STRIPPING FELL AND HIT THE LADDER WORK WA
Penalty: $5,000 · paid: $5,000
FAILURE TO INSTITUTE AND MAINTAIN SAFETY EQUIPMENT MEASURES AND TEMPORARY CONSTRUCTION.NOTE:AT THE TIME OF MY INSPECTION OF A 71 STOYR BUILDING AT ROOF LEVEL RESPONDING TO COMPLAINT #1501106 WHERE A WORKER FELL
Penalty: $10,000 · paid: $10,000
FAIL TO MAINTAIN AND INSTITUTE SAFE OPERATIONS AT THE TIME OF MY IN SPECTION OF AN ACTIVE JOBSITE, ANSWERING A COMPLAINT WHERE A COCOON GUIDING SHOE FELL ON PEDESTRIAN CROSSING OF BUSY STREET, I OBSERVED TH
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35333283M ISSUED 07/25/18 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE TO COMPLY WITH TH
Penalty: $1,250 · paid: $1,250
HOLES NOT COVERED. AT TIME OF INSPECTION OF NEW 72 STORY BLDG ACTIVE JOBSITE BUILDING CURRENTLY AT 50 STORY I OBSERVED NUMEROUS HOLES IN NUMEROUS FLOORS THROUGH OUT JOBSITE AT DIFFERENT LOCAITONS. THIS COND
FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. NOTED: AT TIME OF INSPECTION OBSERVED A PC OF BROKEN VEHICLE. CONCRETE FELL THROUGH THE NETTING AT THE 49TH FLOOR, NETTING AND
Penalty: $10,000 · paid: $10,000
HOUSEKEEPING. AT TIME OF INSPETION OF NEW 72 STORY BUILDING ACTIVE JOBSITE BUILDING AT 5 STORY WITH ACTIVE WORK GOIN GON. I OBSERVED AT NUMEROUS FLOORS LARGE AMOUNTS OF CONSTRUCTION DEBRIS PILED HIGH AND SCATTE
SEC: 3301.9.5. OTHER SIGN. @ TIME OF INSP OF A PROPOSED 72 STORY NEW BLDG @ 36 STORY STAGE ACTIVE JOB SITE. THERE WERE NO EXIT SIGNS POSTED @ EXIT PASSAGEWAY FROM 6TH TO 35TH FLOORS IN CAGE OF FIRE EMERGENCIES.
FAILURE TO INSTITUTE AND MAINTAIN SAFETY EQUIPMENT MEASURES AND TEMPORARY CONSTRUCTION. NOTE: RESPONDING TO COMPLAINT #1477472 WHERE A WORKER WAS HIT FROM FALLING DEBRIS AT GRADE LEVEL FROM UPPER FLOORS. INSPEC
Penalty: $5,000 · paid: $5,000
BC 3301.2 FAILURE TO MAINTAIN ADEQUATE MEANS OF EGRESS. NOTE: AT THE TIME OF MY INSPECTION I OBSERVED THAT MEANS OF EGRESS AND INGRESS INTO SITE WAS BLOCKED BY A 30 CUBIC YARD DUMPSTER, RIGGING OPERATION AND MA
Penalty: $2,500 · paid: $2,500
FAILURE TO SAFEGUARD ALL PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATION. NOTE: AT THE TIME OF INSPECTION I OBSERVED ADJACENT PROPERTY AT EXPOSURE 2 HAD A SETBACK THAT WAS CONSUMED WITH CONCRETE RESIDUE
Penalty: $5,000 · paid: $5,000
BC3301.1.2 FAILURE TO CONFORM TO NYC FIRE CODE - NO FIRE GUARD, FIRE WATCH, WATCHPERSON. NOTE: AT THE TIME OF MY INSPECTION OF A 72 STORY BUILDING AT 32ND FLOOR, CONSTRUCTION WORK IN PROGRESS. I OBSERVED WELDIN
Penalty: $2,500 · paid: $2,500
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. NOTE: AT THE TIME OF MY INSPECTION I OBSERVED CONCRETE LINE BEING ASSISTED AT WORKING DECK WITH A SELF CLIMBING CONCRETE BOOM
Penalty: $2,500 · paid: $2,500
BC3307.7.2 GATES. NOTE: AT THE TIME OF MY INSPECTION OF A 72 STORY BUILDING AT 32ND FLOOR LEVEL, CONSTRUCTION WORK IN PROGRESS. I OBSERVED GATE AT EXPOSURE 1 WAS SWINGING INTO THE PUBLIC AND NOT INSWINGING INTO
Penalty: $625 · paid: $625
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION PLANS AND/OR APPROVED AMENDMENTS. NOTE: AT THE TIME OF MY INSPECTION OF A 72 STORY BUILDING AT 32ND FLOOR LEVEL, CONSTRUCTION WORK IN PROGRESS. I OBSERVED DEBRIS N
Penalty: $2,500 · paid: $2,500
BC3308.5 FAILURE TO MAINTAIN VERTICAL SAFETY NETTING SYSTEM AS REQUIRED. AT TIME OF MY INSPECTION OF A 72 STORY BUILDING CURRENTLY AT 30, I OBSERVED VERTICAL SAFETY NETS ON SEVERAL FLOORS THAT WERE INADEQUATE.
3308.5.3 CABLES @TIME OF INSP OBSERVED ACTIVE JOBSITE THE CABLE SYSTEM PROVED FOR THE PERMETER EDGE(OF)THE BLDG ON FLLS 18,16,15,13, 2 EXP#1 &2 ARE INADEQUATE & ARE LOOSE HANGING & MISSING SOME CABLE IN SOME LO
Penalty: $2,500 · paid: $2,500
3308.5 VERTICAL SAFETY NETTING @TIME OF INSP OBSERVED,ACTIVE JOBSITE THE VERTICAL SAFETY NETTING HAS NOT BEEN MAINTAINED & IS FOUND LOOSE & HANGING IN SOME LOCNS ON FLS 18,16,15,13 EXP# 1&2 PUTTING PERSONS BELO
Penalty: $2,500 · paid: $2,500
3301.2 HOLES NOT COVERED @TIME OF OR INSP OBSERVED ACTIVE JOBSITE HOLES ARE FOUND ON FLS 11 THROUGH 19 IN THE SLAB NOT COVERED AS REQUIRED PUTTING PERSONS ON RISK OF A TRIPPING HAZARDOUS & PUTTING PERSONS ON FL
Penalty: $2,500 · paid: $2,500
HOUSEKEEPING.AT TIME OF INSPECTION ON AN ACTIVE JOBSITE,OBSERVED INADEQUATE HOUSEKEEPING CONSTISTING OF DEBIS,BLDG MATERIALS SCATTERD THROUGHOUT FLOOR 9 AND ABOVE.THIS SITUATION CREAES A TRIP AND FALL HAZARD AL
Penalty: $2,400 · paid: $2,400
FAILURE TO COMPLY W/DOT REGULATIONS.AT TIME OF INSPECION ON AN AVTIVE JOBSITE,OBSERVED MATERIAL STORAGE ON THE STREET ENCLOSED BY AN YODOCK SYSTEM.MATERIAL STORED UP TO 8 FT IN HEIGHT CREATING A HAZARD FOR PED
MATERIAL STORAGE. AT TIME OF INSPECTION ON AN ACTIVE JOBSITE, OBSERVED MATERIAL STORAGE THROUGHOUT JOBSITE. MATERIAL STORAGE ON LEADING EDGE, MATERIAL STORAGE AGAINST RESHORES, CONSISTINGS OF EQUIPMENT OF FORMW
Penalty: $2,400 · paid: $2,400
BC3303.11.1.1:FAILURE TO MAINTAIN PERMANENT STAIRS.AT TIME OF INSPECTION AN ACTIVE JOBSITE,OBSERVED WORKERS WORKING ON 13 FL.PERMANENT STAIRS ERECTED UP TO 9 FL.PERMANENT STAIRS IS OUT OF COMPLIANCE AS THE CODE
Penalty: $1,600 · paid: $1,600
FAILURE TO MAINTAIN SAFE OPERATION ON A ACTIVE JOBSITE.IN RESPONSE TO AN INCIDENT WHERE A WOEKER WAS INJURED BY A PIECE OF PLYWOOD WHILE STRIPPING OPERATIONS GOING ON.WORKER WAS STANDING UNDERNEATH THE STRIPPIN
Penalty: $10,000 · paid: $10,000
INSURANCE(DISABILITY EXPD)IN RESPONSE TO AN INCIDENT WHERE A WORKER GOT STRUCK BY A PIECE OF PLYWOOD ON AN ACTIVE JOBSITE OF PROPOSED 72 STORY BLDG.DOING FURTHER RESEARCH ON BIS, ALERTED ME THAT DISABILITY INSU
Penalty: $1,250 · paid: $1,250
BC3301.2:COMPLY W/FDNY CODE.AT TIME OF INSPECTION ON AN ACTIVE JOBSIE,OBSERVED ON THE SUB-CELLAR 6 CONTAINERS OF LPG,UNSTORE UNPROPERLY.WHEN I ASKED FOR THE FDNY PERMIT FOR THE LPG CONTAINERS,NONE WAS PROVIDED.
Penalty: $1,600 · paid: $1,600
FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35263339L ISSUED ON 11/07/17 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. AT THE TIME ON INSPECTION BLDG IS UNDER AN NB PERMIT#121183799
BC3316.9.2.NO 32 HR RIGGING CENTS.FOR PERSONNEL WORKING WITH RIGGING EQUIPMENT HOISTING OUTSIDE OF A BUILDING ON INSPECTION I ASK FOR THE RIGGING PERSONNEL TO PROVIDE THEIR 32 HR RIGGING CENTS.AS REQUIRED BY BC
ECB Violations (6bgk-3dad), NYC Open Data. As of October 28, 2026.
What are you trying to do here?
Public records for 22 THAMES STREET, Manhattan. Data from NYC Open Data: NYC MapPLUTO, Department of Buildings (DOB NOW, BIS, ECB), Housing Preservation and Development, Landmarks Preservation Commission, ACRIS (NYC Department of Finance), DOF Digital Tax Map. Address lookup by NYC Planning Labs Geosearch. Page updated October 28, 2026.