The decagon that gives every residence a corner window is also the reason wall space at Madison House is the first thing to run out.
15 East 30th Street, 10016
Handel Architects planned Madison House on a decagonal floor plate, a ten sided footprint that removes the interior corner columns and gives every residence a column free glass corner. It is a plan built around the view, and most of what you meet inside follows from that.
With eleven foot ceilings and ten foot windows, the perimeter is nearly all glass, so wall space is scarce. It is also spoken for. The house rules and the alteration agreement bar penetrations of the demising walls between residences, which carry a fire and smoke rating, so televisions, speakers and anything heavy or noisy cannot hang on them. Where the television goes is a plan question here, not a decorating one.
The fan coil closets need louvered doors for return air, so solid doors are out. Window limit stops stay, and the fusible links on select windows have to remain clear, which constrains treatments at the head. On terraces, the facade maintenance rig drops through defined zones that outdoor millwork has to leave alone.
No invasive investigation before closing, so no drywall holes and no lifted boards. Discovery that would normally happen early happens late.
The floors are the forgiving part. Five inch white oak, finished on site rather than prefinished, so they can be sanded and restained in place. Full replacement is rarely necessary.
What is specified here
What the building was delivered with, as specified. Individual residences differ, and owners change things.
Kitchen
Appliances · Gaggenau
Cooktops, combi steam ovens, convection double ovens, refrigeration, and wine refrigeration.
Cabinetry
Custom kitchen cabinetry with finished wood interiors and moldings. Interiors by Gachot Studios.
Range
Induction range.
Bath
Fixtures and fittings · Dornbracht
Platinum matte.
Bathtub · Kaldewei
Toilet · Duravit
Vanity
Custom vanities by Gachot Studios.
Throughout
Flooring
Finished in place wood strip flooring. Strips vary in width, length, and tone.
Stone
Marble or limestone on select interior surfaces, delivered with an impregnating sealer.
Heating and cooling
Centrally controlled fan coil units. Central gas provides heat and domestic hot water.
Laundry
Washing machine and dryer.
Windows
Heat strengthened or tempered glass. Select windows carry fusible links that close them in extreme heat.
Electrical
Data, telephone, and cable outlets pre wired in living rooms and bedrooms. Electrical submetered per unit.
Select units
Fireplace
Four units carry a functional natural gas burning fireplace.
Sources: Sponsor's published materials. Madison House Condominium offering plan, CD180326.
Within walking distance
Building facts
Built
2017
Floors
56
Residences
199
New York City Primary Land Use Tax Lot Output, version 26v1. Tax lot 1008607505.
Public records show 15 EAST 30TH STREET was built in 2017 and rises 56 floors with 199 residential units (NYC MapPLUTO, version 26v2). The Department of Buildings has 50 or more job filings on record for this lot (NYC Open Data).
Public record
Total units
201
Total permits
50 or more
NYC MapPLUTO 26v2, NYC Open Data. Tax lot 1008607505. Violations and permits as of October 27, 2026.
3 filings in the last 24 months, last filing Apr 2026
The record
Permits and violations from the Department of Buildings and the Housing Preservation and Development, newest first.
DOB NOW filings from June 2016.
Mechanical modifications to the existing system. No change in use, egress or occupancy.
Filed estimated cost: $105,175 (as filed, not verified)
INTERIOR RENOVATIONS INCLUDING INSTALLATION OF NON-LOAD BEARING PARTITIONS AND RELATED FINISHES. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
Filed estimated cost: $100,006 (as filed, not verified)
plumbing work to replace gas fireplace on existing roughing
Filed estimated cost: $2,500 (as filed, not verified)
General Construction for rebuilding fireplace enclosure
Filed estimated cost: $49,999 (as filed, not verified)
ERECT NON-ILLUMINATED ACCESSORY BUSINESS CHANNEL LETTER WALL SIGN-B, NO CHANGE TO USE, EGRESS OR OCCUPATION
Filed estimated cost: $2,990 (as filed, not verified)
ERECT NON-ILLUMINATED ACCESSORY BUSINESS CHANNEL LETTER WALL SIGN-A, NO CHANGE TO USE, EGRESS OR OCCUPATION
Filed estimated cost: $2,990 (as filed, not verified)
Removal of facade panels at the roof level and reinstallation of aluminum louvers to allow airflow of the mechanical units at the roof level.
Filed estimated cost: $250,000 (as filed, not verified)
sprinkler/standpipe work for retail buildout for Hastens on cellar & 1st floor (aka 132 Madison Avenue)
Filed estimated cost: $74,936 (as filed, not verified)
sprinkler/standpipe work for retail buildout for Hastens on cellar & 1st floor (aka 132 Madison Avenue)
Filed estimated cost: $74,936 (as filed, not verified)
Plumbing work for retail buildout for Hastens on cellar & 1st floor (aka 132 Madison Avenue)
Filed estimated cost: $59,964 (as filed, not verified)
Structural work for opening of opening in existing structural slab for new stair for retail buildout for Hastens on cellar & 1st floor (aka 132 Madison Avenue)
Filed estimated cost: $39,976 (as filed, not verified)
Mechanical work for retail buildout for Hastens on cellar & 1st floor (aka 132 Madison Avenue)
Filed estimated cost: $144,970 (as filed, not verified)
general construction for retail buildout for Hastens on cellar & 1st floor (aka 132 Madison Avenue)
Filed estimated cost: $489,972 (as filed, not verified)
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE. LIVE LOAD 300PSF.
Filed estimated cost: $1,000 (as filed, not verified)
INSTALLATION OF TEMPORARY ROOF PROTECTION AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY SHALL COMPLY WITH CHAPTER#33 OF 2022 THE NY BUILDING CODE.
Filed estimated cost: $1,000 (as filed, not verified)
Remove/cap plumbing fixtures, remove/cap sprinkler fixtures connected to domestic water, remove/cap gas piping and gas fixtures during alteration of existing 5 story building (126 Madison Avenue) to remove floors 2,3,4 & 5 filed under Alt I # 123520243.
Filed estimated cost: $9,250 (as filed, not verified)
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
Filed estimated cost: $1,000 (as filed, not verified)
Relocating a branch exhaust duct; duct shall tap back into same riser at higher elevation
Filed estimated cost: $5,000 (as filed, not verified)
APPLICATION FILING FOR GENERAL CONSTRUCTION WORK AT APARTMENT 45-B. REMOVAL OF NON LOAD BEARING WALL, CLOSET AND MILLWORK. CONSTRUCT A NEW NON STRUCTURAL WALL OF GLASS AND METAL AND CLOSET. NO CHANGE TO THE USE, EGRESS OR OCCUPANCY.
Filed estimated cost: $19,200 (as filed, not verified)
Architectural changes on the 32nd floor (apt. 32C) as indicated on drawings.
Filed estimated cost: $25,000 (as filed, not verified)
structural work for new mezzanine level and convenience stair
Filed estimated cost: $196,500 (as filed, not verified)
Plumbing work associated with the interior renovation of an existing apartment.
Filed estimated cost: $228,300 (as filed, not verified)
General construction associated with the interior renovation of an existing apartment. There is no change to use, egress, or occupancy.
Filed estimated cost: $570,750 (as filed, not verified)
mechanical work to modify ductwork for revised apartment layout
Filed estimated cost: $20,246 (as filed, not verified)
general construction
Filed estimated cost: $975,497 (as filed, not verified)
sprinkler work
Filed estimated cost: $9,479 (as filed, not verified)
plumbing
Filed estimated cost: $29,750 (as filed, not verified)
INSTALLATION OF HEAVY DUTY SIDEWALK SHED DURING NB CONST, FILED SEP. SIDEWALK SHED SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. SHED INSTALLED ON ROADWAY. DOT PERMITS BY OTHERS.
Filed estimated cost: $40,000 (as filed, not verified)
INSTALLATION OF CONSTRUCTION FENCE AS PER DRAWINGS DURING NB CONST, FILED SEP. CONSTRUCTION FENCE SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. FENCE INSTALLED ON SW / RDWY. DOT PERMITS BY OTHERS.
Filed estimated cost: $20,000 (as filed, not verified)
INTERIOR RENOVATION OF EXISTING APARTMENT 35B ON 35TH FLOOR. NO CHANGE TO USE, OCCUPANCY, OR EGRESS.
Filed estimated cost: $76,300 (as filed, not verified)
INSTALLATION AND USE OF TEMPORARY MOBILE EQUIPMENT AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
Filed estimated cost: $1,000 (as filed, not verified)
TENANT PROTECTION PLAN AS PER PLANS FILED HEREWITH. THIS APPLICATION IS FILED IN CONJUNCTION WITH NB-122128679.
Filed estimated cost: $3,618 (as filed, not verified)
TENANT PROTECTION PLAN AS PER PLANS FILED HEREWITH. THIS APPLICATION IS FILED IN CONJUNCTION WITH NB-122128679.
Filed estimated cost: $3,618 (as filed, not verified)
Support of excavation for single story portion of new building located at the corner of Madison Avenue and East 31 Street. Filed in conjunction with New Building application # 122128679. No change in use, egress or occupancy.
Filed estimated cost: $1,000 (as filed, not verified)
INSTALLATION OF TEMPORARY (13'-26') HIGH PIPE SCAFFOLD AT VARIOUS LEVELS AS PER PLAN. NO CHANGE IN USE EGRESS OR OCCUPANCY,PIPE SCAFFOLD SHALL COMPLY WITH CHAPTER#33 OF 2014 THE NY BUILDING CODE.
Filed estimated cost: $1,000 (as filed, not verified)
INSTALL TEN (10) HEATING HOT WATER BOILERS PER PLANS. ALL PLUMBING, MECHANICAL AND GENERAL CONSTRUCTION IS FILED UNDER A SEPARATE APPLICATION. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Filed estimated cost: $250,000 (as filed, not verified)
INSTALLATION OF PLYWOOD FENCE AS PER DRAWINGS. PLYWOOD FENCE SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. DOT PERMITS BY OTHERS FOR FENCE INSTALLED ON SIDEWALK/ROADWAY.
Filed estimated cost: $57,000 (as filed, not verified)
INSTALLATION OF PLYWOOD FENCE AS PER DRAWINGS. PLYWOOD FENCE SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. DOT PERMITS BY OTHERS FOR FENCE INSTALLED ON SIDEWALK/ROADWAY.
Filed estimated cost: $57,000 (as filed, not verified)
INSTALLATION OF PLYWOOD FENCE AS PER DRAWINGS. PLYWOOD FENCE SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. DOT PERMITS BY OTHERS FOR FENCE INSTALLED ON SIDEWALK/ROADWAY.
Filed estimated cost: $57,000 (as filed, not verified)
Replace first floor exterior bearing walls, replace existing first floor roof beams. Filed in conjunction with Alt Type I # 123520243 (126 Madison Avenue)
Filed estimated cost: $249,985 (as filed, not verified)
Replace first floor exterior bearing walls, replace existing first floor roof beams. Filed in conjunction with Alt Type I # 123520243 (126 Madison Avenue)
Filed estimated cost: $249,985 (as filed, not verified)
INSTALLATION OF A TEMPORARY SCAFFOLD AS PER PLANS IN CONJUNCTION WITH NB CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SCAFFOLD TO COMPLY WITH CHAPTER 33 OF NYC BUILDING CODE OF 2014.
Filed estimated cost: $5,000 (as filed, not verified)
INSTALLATION OF PLYWOOD FENCE DURING BUILDING DEMOLITION, FILED SEPARATELY. PLYWOOD FENCE SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
Filed estimated cost: $5,000 (as filed, not verified)
INSTALLATION OF SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
Filed estimated cost: $10,000 (as filed, not verified)
INSTALLATION OF SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
Filed estimated cost: $10,000 (as filed, not verified)
INSTALLATION OF SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
Filed estimated cost: $10,000 (as filed, not verified)
INSTALLATION OF SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
Filed estimated cost: $10,000 (as filed, not verified)
INSTALLATION OF SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
Filed estimated cost: $10,000 (as filed, not verified)
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE KITCHEN LOCATED AT APT 51D, 51st STORY, 1st APARTMENT FROM SOUTH AT WEST
§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 51D, 51st STORY, 1st APARTMENT FROM EAST AT SOUTH
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
D26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AT REAR ALL STYS.
D26-17.10 ADM CODE PROVIDE READY ACCESS TO BUILDING'S HEATING SYSTEM DOOR TO CELLAR LOCKED R64.
D26-13.03 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES 6TH STY FRONT EAST APT 6B KITCHEN AND BATHROOM. , SECTION '' ''
D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE TO 6TH STY FRONT EAST APT 6B. , SECTION '' ''
§ 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING 4 STY FRONT WEST APT 4A. , SECTION '' ''
§ 27-2005 ADM CODE REFIT ENTRANCE DOOR TO 1 STY REAR WEST APT 1D. , SECTION '' ''
§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CELLAR USE IN CONJUNCTION 1 STY REAR WEST APT 1D DUPLEX. , SECTION '' ''
§ 27-2053 ADM CODE PROVIDE DWELLING WITH A JANITOR OR RESPONSIBLE PERSON OR JANITORIAL SERVICE.
§ 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION 1 STY EAST FIRE STAIR.
§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM AT 1 STY PUBLIC HALL
Source: NYC Department of Buildings and Housing Preservation and Development violations, via NYC Open Data.
Condo documents are recorded at unit level. Search a unit to see them.
HPD maintenance complaints
HPD · NYC Open Data
The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
The Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd
The Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd
The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
39 complaints total.
HPD Maintenance Code Complaints (ygpa-z7cr), NYC Open Data. As of October 27, 2026.
Pre-2016 DOB filings
DOB legacy · NYC Open Data
DOB Job Application Filings (ic3t-wcy2), NYC Open Data. As of October 27, 2026.
DOB legacy violations
DOB BIS · NYC Open Data
FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
CAW TCO DATE ISSUED 12/10/2021 · disposed Aug 14, 2023
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
810 PAID INV 62105952 · disposed Jul 17, 2019
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
CHALLENGE APPROVED · disposed Apr 7, 2019
DESIGN DRAWINGS. AS NOTED AT THE TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE,THE COLUMN FORMS FOR ALL THE COLUMNS SUPPORTING THE 13TH FL SLAB WERE INSTALLED PER COLUMN FORM DRAWINGS WHICH HAD NOT BEEN APPROVED BY FORMWORK ENG'R. REMEDY: COMPLY WITH CODE. ALL FORMWORK DWGS TO BE REVIEWED AND APPROVED BY FORMWORK ENG'R LIC IN NYS
EOR RE-INSPECTED THE COLUMN#2 SUPPORTING13 FL AND IT WAS FOUND TO BE ACCEPTABLE. · disposed Jan 6, 2020
VIOLATION COMPLIED WITH. · disposed Sep 3, 2018
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DDY INV#13321537 · disposed Dec 27, 2017
OK TO DISMISSED DOB VIOLATION. · disposed Jul 7, 2021
BUILDING HAS BEEN FULLY DEMOLISHED AS PER JOB #122367429. CONDITIONS RESOLVED. · disposed Jul 13, 2021
BUILDING HAS BEEN FULLY DEMOLISHED AS PER JOB #122367429. CONDITIONS RESOLVED. · disposed Jul 13, 2021
BUILDING HAS BEEN FULLY DEMOLISHED AS PER JOB #122367429. CONDITIONS RESOLVED. · disposed Jul 13, 2021
BUILDING HAS BEEN FULLY DEMOLISHED AS PER JOB #122367429. CONDITIONS RESOLVED. · disposed Jul 13, 2021
BUILDING HAS BEEN FULLY DEMOLISHED AS PER JOB #122367429. CONDITIONS RESOLVED. · disposed Jul 13, 2021
BUILDING HAS BEEN FULLY DEMOLISHED AS PER JOB #122367429. CONDITIONS RESOLVED. · disposed Jul 13, 2021
BUILDING HAS BEEN FULLY DEMOLISHED AS PER JOB #122367429. CONDITIONS RESOLVED. · disposed Jul 13, 2021
BUILDING HAS BEEN FULLY DEMOLISHED AS PER JOB #122367429. CONDITIONS RESOLVED. · disposed Jul 13, 2021
DOB BIS Violations (3h2n-5cm9), NYC Open Data. As of October 27, 2026.
ECB violations
Environmental Control Board · NYC Open Data
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B AND 9B REPORT OF CRITICAL EXAMINATION DOCUEMNTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #902424. REMEDY: SUBMIT ACCEPTAB
FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #802434 REMEDY:SUBMIT ACCEPTABLE REQUIRED TE
FAILURE TO NOTIFY THE DEPARTMENT OF AN ACCIDENT OR INCIDENT THAT RESULTED IN A FATALITY OR AN INJURY.NOTE A WORKER SUFFERED AN INJURY TO HISRIGHT WRIST WHEN UNLOADING A BUNDLE OF 2X4'S.WORKER WAS TAKEN TO CITY
FAILURE TO NOTIFY THE DEPT. OF AN ACCIDENT/INCIDENT THAT RESULTED IN AFATALITY OR AN INJURY.NOTE:A WORKER WERE INJURED WHEN THE METAL STUD'SSHARP EDGE CUT HIS FINGERS.WORKER WAS TAKEN TO HOSPITAL.AS PER CHECK
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS OR AMENDMENTSAT THE TIME OF MY INSPECTION OF A PROPOSED 56 STORY NEW BUILDING WITH CONSTRUCTION I OBSERVED SUPPORTED SCAFFOLDING IN PLACE AT EXPOSURE#3 3
Penalty: $1,250 · paid: $1,250
FAILURE TO INSTITUTE SAFETY EQUIPMENT MEASURES.AT THE TIME RESPONDING TO AN INCIDENT WHERE THE WORKER GUZMAN GONZALEZ WAS PERFOMING INSTALLATION WORK AT LEVEL 59 PENTHOUSE USING 3FT A PRAM LADDER WHILE THE LADD
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.NOTED:AT TIME OF MY INSPECTION OF A NEW 56 STORIE BUILDING,CONSTRUCTION IN PROGRESS,BUILDING TOPPED OFF,I OBSERVED SUPPORTED S
FAILURE TO NOTIFY THE DEPARTMENT OF AN ACCIDENT/INCIDENT THAT RESULTEDIN A FATALITY OR AN INJURY.NOTE DURING WINDOWS INSTALLATION,A WORKER GOT HIS HAND CUT.HE LEFT TO GO TO AN URGENT CARE CENTER TO RECEIVE TREA
FAILURE TO INSITITUTE AND MAINTAIN SAFETY MEASURES AND STANDARS NOTE: IN RESPONSE TO INCIDENT WHERE WORKER GOT INJURED IT WAS REPORTED WHILEINSTALLING LARGE GLASS WINDOW STONE AT 1ST STORY STREET LEVEL USING SP
WORK DOESNT CONFORM TO APPROVED CONST DOCS &/OR APPROVED AMENDMENTS ATOI OF ACTIVE 56STYNB,I OBSERVED SPYDER CRANE ON 50FL BEING MOBILIZED FOR DAY TO INSTALL GLAZING@EXP3.ON REV OF APPROVED PLANS,IN PARTICULAR
FAILURE TO INSTITUTE SAFETY MEASURES IN RESPONSE TO INCIDENT WHERE WORKER GOT INJURED AT 56 STORY NEW BUILDING ACTIVE JOBSITE.SSM AND CONSTRUCTION SUPER BOTH STATED THAT WORKER JUMPED FROM 4TH STORY SETBACK ONT
Penalty: $5,000 · paid: $5,000
FAILURE TO NOTIFY THE DEPT OF AN ACCIDENT/INCIDENT THAT RESULTED IN A FATALITY OR AN INJURY. NOTE=A WORKER WAS USING STILTS WHEN THE STILTS BROKE,AND THE WORKER FELL ONTO THE FLOOR. THE WORKER SUFFERED ARM AND
FAILURE TO INSTITUTE AND MAINTAIN SAFETY MEASURES DURING OPERATIONS.NOTE:AT TIME OF MY INSPECTION OF A 56 STORY N.B IN RESPONSE TO AN INCIDENT REPORTED WHERE ONE WORKER ON STILTS FELL AND INJURED HAS RIGHT LEG
FAILURE TO NOTIFY THE DEPT OF AN ACCIDENT OR INCIDENT THAT RESULTED INA FATALITY OR INJURY. A WORKER WAS MOVING SHEET METAL WHEN FRANE FELL OVER ONTO HIS LEG. AMBULANCE WAS CALLED & TAKEN TO THE HOSPITAL. AS PE
PARTIAL STOP WORK ON SUPPORTED SCAFFOLDS LAYING BLOCKS. ALLOWED TO WORK ONLY TO MAKE SAFE/REMOVE. NOTE: AT TIME OF INSPECTION I OBSERVED SUPPORTED SCAFFOLD NOT TO CODE SPECIFICATIONS 1)FRAME NOT TIED OFF 2)GUAR
Penalty: $2,500 · paid: $2,500
PERMIT HOLDER FAILED TO ENSURE WORKERS ATTEND PRE-SHIFT SAFETY MEETINGNOTE:AT THE TIME OF MY INSPECTION OF A 56 STORY CONSTRUCTION SITE,CONSTRUCTION WORK IN PROGRESS THERE CONSIST OF CARPENTRY,UPON REQUEST FOR
Penalty: $5,000 · paid: $5,000
FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33.NOTE:AT THE TIME OF MY INSPECTION OF 58 STORY BUILDING RESPONDING TOA COMPLAINT WHERE AN INDIVIDUAL WAS MOVING MATERIAL ON 41 FLOOR.I OBSE
Penalty: $625 · paid: $625
FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION.NOTE:AT THE TIME OF MY INSPECTION OF A 56 STORY BUILDING(NEW)RESPONDING TO AN INCIDENT ON THE 41ST FLOOR WHERE A WORKER HAD AN I
Penalty: $2,500 · paid: $2,500
FAILURE TO COMPLY WITH MANUFACTURER SPECIFICATIONS.NOTE:AT THE TIME OFMY INSPECTION OF A 58 STORY BUILDING RESPONDING TO AN INCIDENT WHERE AND WORKER WAS MOVING SHEET MATERIAL ON THE 41 FLOOR WHEN MATERIAL FALL
Penalty: $2,500 · paid: $2,500
PROHIBITED OUTDOOR ADVERTIZING COMPANY ON SIDEWALK SHED.NOTED:AT TIME OF MY INSPECTOIN OF A NEW 56 STORY BUILDING CONSTRUCTION IN PROGRESS IOBSERVED UPON ENTRY TO THE SITE THAT THE SIDEWALK SHED AT EXPOSURES 3
Penalty: $10,000 · paid: $10,000
BC33012/279009(A)-HOLES/OPENING NOT COVERED.NOTED:AT TIME OF MY INSPECTION OF A NEW 56 STORY BUILDING,CONSTRUCTION IN PROGRESS,I OBSERVED 5 HOLES APPROX 4 INCHES WIDE UNCOVERED ON THE 39TH FLOOR I ALSO OBSERVED
FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. 56 STORY NEW BUILDING AT BULKHEAD LEVEL AT THE TIME OF MY INSPECTION I OBSERVED THE EGRESS/INGRESS WAS OBSTRUCTED ON TEH 47TH
Penalty: $5,000 · paid: $5,000
BC3303.2.3 UNSAFE WIRING ON JOBSITE. 56 STORY NEW BUILDING AT BULKHEADLEVEL. AT THE TIME OF MY INSPECTION I OBSERVED TEMPORARY LIGHTS INSTALLED THROUGHOUT STAIRWAY AREA. THE LIGHTS WAS UNSAFELY SPLICED AND EVEN
Penalty: $2,500 · paid: $2,500
FAILURE TO MAINTAIN DISPLAY ON SITE DOCUMENTS REQUIRED BY CHAPTER 33, 56 STORY NEW BUILDING AT BULKHEAD LEVEL AT THE TIME OF MY INSPECTION I OBSERVED THE COCOON SYSTEM WAS BEING DISMANTLED ON FLOORS THROUGH
Penalty: $2,500 · paid: $2,500
BC3314.4.4.1 FAILURE TO PROVIDE ALL ATTACHMENTS FOR SUPPORTED SCAFFOLD56 STORY NEW BUILDING AT BULKHEAD LEVEL. AT THE TIME OF MY INSPECTION I OBSERVED 2 SCAFFOLD STAIR TOWER INSTALLED AT THE ROOF LEVEL LEADING
Penalty: $2,500 · paid: $2,500
WORK CONTRARY TO WORK DOCUMENTS. AT THE TIME OF MY INSPECTION I OBSERVED A 3" (APPRX) GAP BETWEEN THE STAIR AND THE LANDING (SLAB) UPON MY REQUEST FOR THE DETAILS FOR THE GAP DOCUMENTS REVEALED THAT THERE WAS
Penalty: $2,500 · paid: $2,500
FAILED TO NOTIFY THE DEPARTMENT OF NA INCIDENT THAT RESULTED IN A FATALITY OR INJURT ONE WORKERS UNLOADING SHEETINGS ON AN "A" FRAME AND SHEETROCK COLLAPSED ON HIS LEG THE OWRKER SUPPORTED A POSSIBLY BROKEN LEF
INADEQUATE HANDRAILS. NOTE: AT THE TIME OF MY INSPECTION OF AN ACTIVE JOBSITE,RESPONDING TO INCIDENT REPORTED BY THE SITE SAFETY MANAGER,WHERE A WORKER WALKING DOWN THE STAIRS CUT HIS KEFT HAND ON THE STAIRS
Penalty: $6,250 · paid: $6,333
FAILURE TO INSTITUTE MAINTAIN SAFETY EQUIPMENT MEASURE OR TEMPORARY CONSTRUCTION. NOTE: AT TIME OF INCIDENT. I OBSERVED AT ACTIVE 51 STORYBUILDING DEVELOPMENT A PLUMBER WAS OFF LOADING MAERIALS WHEN A SINGLE
Penalty: $5,000 · paid: $5,000
FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION IN RESPONSE TO INCIDENT WHERE WORKERS UNLOADING CAST IRONPIPE OFF A FLATBED TRUCK AT LOADING DOCK EXPOSURE 3PC OF PIPE ROLLED O
FAILED TO NOTIFY THE DEPARTMENT OF AN INCIDENT THAT RESULTED IN A FATALITY OR INJURY A WORKERS GOT HEART WHEN A PIPE FELT IN HIS ANKLE HE WS TAKEN TO THE HOSPITAL BY AN AMBULANCE AS PER THE DEPARTMENT RECORDS T
DRIVER/OPERATOR MICHAEL CUFFIE NYS DL 856002617 WHILE IN PROCESS OFF FOLDING PU HIS KNUCKLE BOOM LIC#NY29970 PC, THE HEAD SECTION SLIPPED OUT FORM THE MIDDLE SECITON WHERE IT WAS ATTACHED AND FELL APPRX 6'
WORK CONTRARY TO CONSTRUCTION DOCUMENT. 56 STORY NEW BUILDING AT 53 STORY.AT THE TIME OF MY INSPECTION I OBSERVED THE HORIZONTAL NETTING ON THE PERIMETER OF THE BUILDING WAS ON THE 44TH STORY LEVEL WHILE
Penalty: $1,250 · paid: $1,250
BC 3308.5FAILURE TO MAINTAIN VERTICAL NETTING SYSTEM AS REQUIRED.56 STORY NB AT 53 STORY.AT THE TIME OF MY INSPECTION I OBSERVED THE ZERO CABLE ON VARIOUS FLS.WAS NOT FASTENED TO THE SLAB AS REQUIRED,THIS POSES
Penalty: $2,500 · paid: $2,500
FAILURE TO SAFEGUARD ALL PERSONS AND PROPERLY AFFECTED BY CONSTRUCTIONOPERATIONS. 56 STORY NEW BUILDING: 53RD STORY. AT THE TIME OF MY INSPECTION I OBSERVED OPENINGS IN THE FLOOR, ON THE 52ND STORY, AS WIDE AS
Penalty: $10,000 · paid: $10,000
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PR SECTION REQUIREMENT. 56 SOTRY NEW BUILDING AT 53RD STORY. AT THE TIME OF INSPECTION I OBSERVEDTHE HOUSEKEEPING ON VARIOUS FLOORS WAS NOT BEING MAINTAINED.THERE WAS
FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS.AT THE TIME OF INSPECTIOIN RESPONDING TO COMPLAINT #1505343WHERE IT WAS REPORTED THAT NAILS AND PIECES OF DEBRI FELL INTO A CAR
FAILURE TO MAINTAIN . AT TIME OF INSPECTION IN RESPONSE TO COMPLAINT #1498249 OBSERVED SIDWALK SHED IN PLACE,NOT MAINTAINED ACCORDING TO CODE SPECIFICATIONS.THE PROTRUDING BOLTS WERE NOT CAPPED CONSEQUENTLY
Penalty: $2,400 · paid: $2,464
FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL# 802434. REMEDY: SUBMIT REQUIRED TECHNICAL REPORT.
3308.5-VERTICAL SAFETY CABLES(NETTING)AT TIME OF INSPECTION F NEW 56 STORY BUILDING ACTIVE JOBSITE BUILDING CURRENTLY 13 STORY I OBSERVED ON NUMEROUS FLOORS VERTICAL SAFETY NETIING WAS INADQUATE THROUGHOUT BUIL
3301.2-HOLES NOT COVERED.AT TIME OF INSPECTION OF NEW 56 STORY BUILDING ACTIVE JOBSITE.BUILDING CURRENTLY AT 13 STORY , IOBSERVED ON NUMEROUS FLOORS AND DIFFERENT LOCATION HOLES,MORE THAN 2'WIDE AT DIFFERENT LO
Penalty: $2,500 · paid: $2,500
HOUSEKEEPING: AT TIME OF INSPECTION I OBSERVED PILES OF COMBUSTIBLE MATERIAL AT VARIOUS LOCATIONS THROUGHOUT JOB SITE PLYWOOD 2X4S AND OTHERCONSTRUCTION DEBRIS NOT PLACED IN CODE COMPLIANT BINS CREATES A POTENT
Penalty: $2,500 · paid: $2,500
28-103.8 MATTERS NOT PROVIDED FOR EMBEDDED FALL ARREST SYSTEM LOGS. AS NOTED: AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE, OBSERVED D-RINGS EMBEDDED INTO CONCRETE SLAB FL #2-13. FAILED TO PROVIDE D-RIN
FAILURE TO MAINTAIN SAFETY MEASURES AT TIME OF INSPECTION IN RESPONSE TO INCIDENT IN WHICH CONCRETE COLUMN FORMWORK FAZLED AND BLEWOUT I OBSERVED UNCOVERED COLUMN REBAR BELOW WAIST HEIGHT-LESS THAN 4'UNCOVERED
Penalty: $2,500 · paid: $2,500
FAILURE TO PROVIDE PE DESIGN DRAWINGS - COLUMN FORMWORK. AS NOTED: AT TIME OF INSPECTION, ON AN ACTIVE CONSTRUCTION SITE, OBSERVED FORMWORK FAILURE AT FLOOR 12-13 COLUMN #2. APPROX 5CY OR 14K PSI LEAKED OUT AT
Penalty: $2,500 · paid: $2,500
FAILURE TO MAINTAIN SAFE OPERATIONS. AT TIME OF RESPONSE TO INCIDENT IN WHICH IT WAS TOLD TO ME BY SSM/CSM THAT THE COLUMN AT NORTHWEST CORNER OF BLDG HAD BLOWN OUT DURING CONCRETE PLACEMENT OPERATIONS AT THE
Penalty: $10,000 · paid: $10,000
OPERATION OF A CRANE WITHOUT A CERTIFICATE OF ONSITE INSPECTION. WHEN I RESPONDED TO COMPLAINT #1472802 FOR A CRANE ONSITE WITHOUT A PERMIT, I OBSERVED THE HOISTING OF CONSTRUCTION MATERIALS BY A CRANE OPERATE
OPERATING AN ARTICULATING BOOM CRANE WITHOUT A CERTIFICATE OF OPERATION. AT THE TIME OBSERVED EQUIPMENT WAS BEING USED OUTSIDE OF THE EXEMPTION OF BC 3319.3(10) IN THAT THE ABC WAS NOT USED EXCLUSIVELY TO LOAD
OPERATION OF A CRANE WITHOUT A CERTIFICATE OF ONSITE INSPECTION. AT TIME OF RESPONDING TO A COMPLAINT FOR A CRANE ONSITE WITHOUT A PERMIT, I OBSERVED THE OPERATION OF A CRANE BY OPERATOR FRANKLIN PINZON HOISTIN
OPERATING A ARTICULATING BOOM CRANE WITHOUT A CERTIFICATE OF OPERATION. AT TIME OBSERVED EQUIPMENT WAS BEING USED OUTSIDE THE EXEMPTION OF BC 3319.3(10) IN THAT THE ABC WAS NOT BEING USED EXCLUSIVELY FOR LOADIN
ECB Violations (6bgk-3dad), NYC Open Data. As of October 27, 2026.
Certificates of occupancy
DOB · NYC Open Data
DOB NOW CofO (pkdm-hqz6) and DOB Legacy CofO (bs8b-p36w), NYC Open Data. As of October 27, 2026.
What are you trying to do here?
Public records for 15 EAST 30TH STREET, Manhattan. Data from NYC Open Data: NYC MapPLUTO, Department of Buildings (DOB NOW, BIS, ECB), Housing Preservation and Development, Landmarks Preservation Commission, ACRIS (NYC Department of Finance), DOF Digital Tax Map. Address lookup by NYC Planning Labs Geosearch. Page updated October 27, 2026.